MAGUS Bio VD300 LCD Biological Inverted Digital Microscope #83013

€3,223.30
Item in stock: Italy
3 to 5 working days
SKU
83013

More Information
EAN/UPC 5905555018102
Manufacturer MAGUS
Manufacturer Code 83013
Price €3,223.30

MAGUS Bio VD300 LCD is a biological microscope of an inverted design for studying samples in laboratory ware up to 70 mm high and with a bottom thickness up to 1.2 mm. The objects of study can be colonies of cells, tissue cultures, biological fluids, etc. The samples do not require mandatory pre-staining. The observations are made in transmitted light. Microscopy techniques: brightfield and phase contrast. The microscope is suitable for routine and research work, and teaching.

Descrizione

MAGUS Bio VD300 LCD is a biological microscope of an inverted design for studying samples in laboratory ware up to 70 mm high and with a bottom thickness up to 1.2 mm. The objects of study can be colonies of cells, tissue cultures, biological fluids, etc. The samples do not require mandatory pre-staining. The observations are made in transmitted light. Microscopy techniques: brightfield and phase contrast. The microscope is suitable for routine and research work, and teaching.

Microscope in use »

Digital camera

The MAGUS CHD30 digital camera is equipped with a 2MP sensor and produces realistic Full HD images at a resolution of 1920x1080px. The camera features high light sensitivity, auto focus function, and it is suitable for fluorescent observations.The camera uses an HDMI interface to connect directly to a TV, monitor, or projector. In this mode, the camera operates autonomously without a connection to a PC. The HDMI interface provides a high and stable transfer rate from the camera to the external screen. You can connect it to a PC via Wi-Fi.Video is recorded at 60fps or 25fps depending on the video output interface.The camera combines high FPS and high bandwidth HDMI. Therefore, videos are vivid with no freezes or gaps between frames. At maximum resolution, the image is well-detailed, moving objects are visible without bugs, and object movement is displayed without delays.

Monitor

MAGUS MCD monitors work in combination with MAGUS CHD cameras to form a complete imaging system for MAGUS microscopes.
The connection to the camera occurs via its HDMI interface. The monitor displays real-time images. Its IPS LCD display has a wide viewing angle, high brightness, and good contrast. When looking at the screen even from a large angle, the image is not distorted. The screen size is 13.3''.
The monitor can be installed on a horizontal surface using a folding stand or mounted directly on a camera or tripod.

Optics

The microscope is equipped with a classic trinocular head, the trinocular tube is used for mounting a digital camera. The camera is not included in the set. The beam splitting is 50/50.Four included or additional objectives can be mounted in the revolving nosepiece. All objectives are designed to be used with laboratory ware and have a long working distance. There are 3 plan achromatic objectives for brightfield and 1 plan achromatic objective for the phase contrast technique.

Illumination

The transmitted light source is a 9W LED. The high power of the LED makes the illumination of the working area bright enough to work with all objectives and with any microscopy technique. The brightness adjustment does not change the color temperature. The LED lifetime is about 50,000 hours without LED replacement.The condenser has a slot for a phase contrast slider (included). The phase contrast rings can be centered. The installation of the slider saves time when switching between the microscopy techniques.

Stage and focusing mechanism

Fixed mechanical stage. It is equipped with a dish holder (three dish holders of different sizes are included). The dishes can be moved along the X and Y axes by a mechanical attachment. The coaxial coarse and fine focusing mechanism provides accurate and fast focusing. The coarse focusing has a lock mechanism and tension adjustment.

Accessories

The optional accessories line includes phase objectives, eyepieces, digital cameras, and calibration slides.

Key features of the microscope:

  • Brightfield and phase contrast microscopy techniques in the transmitted light; studying samples in laboratory ware
  • Digital camera is mounted in the trinocular tube
  • 9W LED transmitted light illuminator with adjustable brightness and a long lifetime
  • Fixed stage with two-axis movement, 3 dish holders for different sizes included
  • Optional accessories to improve microscope performance

Key features of the camera:

  • The camera operates autonomously without a connection to a PC via the HDMI interface. It can be connected to a PC via USB2.0 interface
  • The auto focus in HDMI mode makes it easier to adjust image sharpness
  • The camera resolution is 1920x1080px – an ideal choice for displaying images on a Full HD monitor
  • 60fps for observing moving objects, recording video and moving the preparation without jerkiness or delays
  • 25fps via Wi-Fi – enough for focus adjustment and image processing using the software
  • SONY color CMOS sensor – low noise level and high light sensitivity
  • Software with photo, video recording, editing, external display functions, linear and angular measurements

The kit includes:

  • MAGUS CHD30 Digital Camera (digital camera, HDMI cable (1.5m), USB mouse, 32GB SD memory card, USB Wi-Fi adapter, AC power adapter 12V/1A (Euro), installation CD with drivers and software, user manual and warranty card)
  • MAGUS MCD20 LCD Monitor
  • Stand with the built-in power supply, transmitted light source, focusing mechanism, stage, condenser with a slot for phase-contrast slider, and revolving nosepiece
  • Trinocular head
  • Infinity plan achromatic objective: PL 10x/0.25 WD 4.3mm
  • Infinity plan achromatic objective: PL L20х/0.40 WD 8.0mm
  • Infinity plan achromatic objective: PL L40х/0.60 WD: 3.5mm
  • Infinity plan achromatic objective: PHP2 10x/0.25 phase WD 4.3mm
  • Eyepiece 10x/22mm with long eye relief (2 pcs.)
  • Eyecup (2 pcs.)
  • Centering telescope
  • Phase contrast slider with centering phase rings
  • Mechanical attachment for moving the specimen
  • Dish holder (3 pcs.)
  • C-mount camera adapter
  • Color filter
  • AC power cord
  • Dust cover
  • User manual and warranty card

Available on request:

  • 10x/22mm eyepiece with a scale
  • 12.5x/14mm eyepiece (2 pcs.)
  • 15x/15mm eyepiece (2 pcs.)
  • 20x/12mm eyepiece (2 pcs.)
  • 25x/9mm eyepiece (2 pcs.)
  • Infinity plan achromatic objective: PL 4x/0.10 WD 21mm
  • Infinity plan achromatic objective: PHP2 20x/0.40 phase WD 8.0mm
  • Infinity plan achromatic objective: PHP2 40x/0.60 phase WD 3.5mm
  • Calibration slide
BrandMAGUS
Warranty5 years
EAN5905555018102
Package size (LxWxH)64x42x67 cm
Shipping Weight20.75 kg
=== Delimiter ===Microscope specifications
Typebiological, digital, light/optical
Microscope head typedigital screen/PC monitor, trinocular
HeadSiedentopf
Head inclination angle45 °
Magnification, x100 — 400
Magnification rangefrom 200x to 800x
Magnification, x (optional)40–500/600/800/1000
Eyepiece tube diameter, mm30
Eyepieces10х/22mm, eye relief: 10mm (*optional: 10x/22mm with scale, 12.5x/14; 15x/15; 20x/12; 25x/9)
Objectivesinfinity plan achromatic: PL 10x/0.25, PL 20x/0.40, PL 40x/0.60, PHP2 10x/0.25 phase; parfocal distance 45mm (*optional: PL 4x/0.10, PHP2 20x/0.40 phase, PHP2 40x/0.60 phase)
Revolving nosepiecefor 4 objectives
Working distance, mm21.0 (4x); 4.3 (10x); 8.0 (20х); 3.5 (40x)
Interpupillary distance, mm48 — 75
Stage moving range, mm77/112
Stage featuresfixed, with mechanical attachment for moving the specimen; dish holders: 29x77mm, Ø90mm; 34x77.5mm, Ø68.5mm; 57x82mm, Ø60mm
CondenserNA 0.6, working distance: 70mm; with adjustable aperture diaphragm and a phase contrast slider slot
Diaphragmadjustable aperture
Focuscoaxial, coarse (with coarse focusing tension adjustment and a lock knob), and fine (0.002mm)
BodyCNC aluminum alloy
IlluminationLED
Brightness adjustmentyes
Power supply220±22V, 50Hz, AC 110–220V, DC 5–12V/1A (Type-C), AC network
Light source type9W
Light filtersyes
Operating temperature range, °C5 — 35
Special featuresphase contrast slider for a 10x objective with a centerable phase ring
Ability to connect additional equipmentUSB mouse, Wi-Fi adapter (USB)
User levelexperienced users, professionals
Assembly and installation difficulty levelcomplicated
Applicationlaboratory/medical
Illumination locationupper (transmitted light)
Research methodbright field, phase-contrast microscopy
Pouch/case/bag in setdust cover
=== Delimiter ===Camera specifications
SensorSONY CMOS
Color/monochromecolor
Megapixels2
Maximum resolution, pix1920x1080
Sensor size1/1.9" (7.20x4.05mm)
Pixel size, μm3.75x3.75
Auto focusyes
Interface connectorsHDMI 1.4, Wi-Fi
Memory cardSD up to 32GB
Wi-Fi settings802.11n, 150Mbps, 20dBm
Light sensitivity1120mV with 1/30s
Signal/noise ratio0.15mV at 1/30s
Exposure time0.06ms–918ms
Video recordingyes
Frame rate, fps at resolution25@1920x1080 (Wi-Fi), 60@1920x1080 (HDMI)
Place of installationtrinocular tube, eyepiece tube instead of an eyepiece
Image format*.jpg
Video format*.asf
Spectral range, nm380–650 (built-in IR filter)
Shutter typeERS (electronic rolling shutter)
SoftwareHDMI: built-in; USB: MAGUS View
System requirementsWindows 8/10/11 (32bit and 64bit), Mac OS X, Linux, up to 2.8GHz Intel Core 2 or higher, minimum 4GB RAM, USB2.0 port, RJ45, 19" or larger display (with USB connection)
Mount typeC-mount
Camera power supplyDC adapter 12V, 1A
Specifications of the DC power adapterinput: AC voltage 100–240V, 50/60Hz, output: DC voltage 12V/1A
Camera operating temperature range, °С-10 — 50
Operating humidity range, %30 — 80
=== Delimiter ===Monitor specifications
Type of matrixIPS
Display diagonal, inch13.3
Display resolution, px1920x1080 (Full HD)
Aspect ratio16:9
Brightness, cd/m²400
Number of displayed colors16.7 m
Contrast1000:1
Horizontal/vertical viewing angle, °178/178
Size of the visible screen area (WxH), mm295x165
Pixel pitch (WxH), mm0.154x0.154
Frequency of optical source, Hz60
Type of matrix backlightLED
LED backlight lifetime, h50000
InterfaceHDMI
Power consumption, W12 (max.)

Reviews

Write Your Own Review
You're reviewing:MAGUS Bio VD300 LCD Biological Inverted Digital Microscope #83013
Your Rating
Italiano Deutsch English Français Español